High Power Density Modules are designed for applications requiring high performance modules where the devices (lasers, thermal stabilization of test bench device for chip production etc .) produce a large amount of heat per square mm.
Operating Parameters:
- Maximum temperature for short time (to mount a module into unit): 200°С
- Maximum operation temperature: 150°С
- Recommended operation current: 0 .5 – 0 .7 of Imax .
- Minimal cycling stability in ON-OFF power cycling mode: over 60 000 cycles (cycle time is 60/60 seconds)
- Minimal cycling stability in 20/80 °С power cycling mode: over 25 000 cycles